SelfCooking Center® 202 E
(20x2/1-40x1/1 GN)
Capacity: 20 x 2/1 GN
Lengthwise loading for: 2/1, 1/1 GN
Number of meals per day: 300-500
Width: 1.084 mm
Depth: 996 mm
Height: 1.782 mm
Minimum distances (left, right, back): 50 mm
Recommended distance for service work (left): 500 mm
Minimum distance on left for heat sources: 350 mm
Water supply (pressure hose): 3/4'' / Ø 1/2''
Water pressure (Flow pressure): 150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar
Minimum flow rate for filter and soft water system: 15,0 l/h
Water drain: DN 50 mm
Connected load: 62 kW
Fuse protection: 3 x 100 A
Mains connection: 3 NAC 400V
"Moist heat" connection: 54 kW
"Dry heat" connection: 60 kW
Weight (net): 332 kg
Cable cross-section: 5 x 25 mm2
Marks of conformity: CE, IPX5, VDE, UL, CUL, NSF, KEMA, PCT, GS, DVGW, SVGW, WRAS, KIWA
Latent heat load: 12.500 kJ/h
Sensitive heat load: 14.286 kJ/h
Required air volume (unit free-standing in room): 2.123 m3/h
Required air volume (unit with one side against the wall): 1.337 m3/h
Required air volume (unit with two sides against the wall): 849 m3/h
SelfCooking Center® 202 G (20x2/1-40x1/1 GN)
Capacity: 20 x 2/1 GN
Lengthwise loading for: 2/1, 1/1 GN
Number of meals per day: 300-500
Width: 1.084 mm
Depth: 996 mm
Height: 1.782 mm
Height incl. gas draft diverter: 2.021 mm
Minimum distances (left, right, back): 50 mm
Recommended distance for service work (left): 500 mm
Minimum distance on left for heat sources: 350 mm
Water supply (pressure hose): 3/4'' / Ø 1/2''
Water pressure (Flow pressure): 150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar
Minimum flow rate for filter and soft water system: 15,0 l/h
Water drain: DN 50 mm
Electricity connection: 1,1 kW
Weight (net): 370,5 kg
Fuse protection: 1 x 16 A
Mains connection: 1 NAC 230 V
Cable cross-section 3 x 2,5 mm2
Gas supply/connection: 3/4"
Connected flow pressure, natural gas H G20: 18 - 25 mbar
Connected flow pressure, natural gas L G25: 20 - 30 mbar
Connected flow pressure, liquefied gas G30: 25 - 57,5 mbar
Connected flow pressure, liquefied gas G31: 25 - 57,5 mbar
Exhaust gas duct: A3 (nur Typ 61), B13, B23
Rated thermal load Liquid gas LPG total: 67 kW
Rated thermal load Liquid gas LPG "Moist heat": 53 kW
Rated thermal load Liquid gas LPG "Dry heat": 67 kW
Rated thermal load natural gas total: 64 kW
Rated thermal load natural gas "Moist heat": 51 kW
Rated thermal load natural gas "Dry heat": 64 kW
Marks of conformity: CE, GS, KEMA, DVGW, SVGW, KIWA, IPX5, NSF, GASTEC QA, AGA/CSA, JIA, PCT
Latent heat load: 11.583 kJ/h
Sensitive heat load: 13.636 kJ/h
Required air volume (unit free-standing in room): 2.123 m3/h
Required air volume (unit with one side against the wall): 1.337 m3/h
Required air volume (unit with two sides against the wall): 849 m3/h