| SelfCooking Center® 62 G (6x2/1-12x1/1 GN) |
| Capacity: |
6 x 2/1 GN |
| Lengthwise loading for: |
2/1, 1/1 GN |
| Number of meals per day: |
60-160 |
| Width: |
1.069 mm |
| Depth: |
971 mm |
| Height: |
757 mm |
| Height incl. gas draft diverter: |
996 mm |
| Minimum distances (left, right, back): |
50 mm |
| Recommended distance for service work (left): |
500 mm |
| Minimum distance on left for heat sources: |
350 mm |
| Water supply (pressure hose): |
3/4'' / Ø 1/2'' |
| Water pressure (Flow pressure): |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
| Minimum flow rate for filter and soft water system: |
8,0 l/h |
| Water drain: |
DN 50 mm |
| Electricity connection: |
0,4 kW |
| Weight (net): |
168 kg |
| Fuse protection: |
1 x 16 A |
| Mains connection: |
1 NAC 230 V |
| Cable cross-section |
3 x 2,5 mm2 |
| Gas supply/connection: |
3/4" |
| Connected flow pressure, natural gas H G20: |
18 - 25 mbar |
| Connected flow pressure, natural gas L G25: |
20 - 30 mbar |
| Connected flow pressure, liquefied gas G30: |
25 - 57,5 mbar |
| Connected flow pressure, liquefied gas G31: |
25 - 57,5 mbar |
| Exhaust gas duct: |
A3 (nur Typ 61), B13, B23 |
| Rated thermal load Liquid gas LPG total: |
23 kW |
| Rated thermal load Liquid gas LPG "Moist heat": |
21 kW |
| Rated thermal load Liquid gas LPG "Dry heat": |
23 kW |
| Rated thermal load natural gas total: |
21,5 kW |
| Rated thermal load natural gas "Moist heat": |
20 kW |
| Rated thermal load natural gas "Dry heat": |
21,5 kW |
| Marks of conformity: |
CE, GS, KEMA, DVGW, SVGW, KIWA, IPX5, NSF, GASTEC QA, AGA/CSA, JIA, PCT |
| Latent heat load: |
4.167 kJ/h |
| Sensitive heat load: |
5.000 kJ/h |
| Required air volume (unit free-standing in room): |
719 m3/h |
| Required air volume (unit with one side against the wall): |
453 m3/h |
| Required air volume (unit with two sides against the wall): |
288 m3/h |