SelfCooking Center® 101 E (10x1/1 GN)
Capacity (Steam pans):
Capacity (half size sheet pans):
Capacity (GN-container/grids): 10 x 1/1 GN
Loading for: 1/1, 1/2, 2/3, 1/3, 2/8 GN
Number of meals per day: 80-150
Width: 847 mm
Depth: 771 mm
Height: 1.017 mm
Minimum gap (left, right, back side): 50 mm
Recommended gap fo servicing (left side): 500 mm
Minimum gap if heat sources are acting on left side: 350 mm
Water connection (pressure hose): 3/4'' / Ø 1/2''
Note:
Water pressure (Flow pressure): 150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar
Minimum flow rate for soft water system: 6,3 l/h
Water drain: DN 50 mm
Note:
Connected load: 19 kW
''Moist heat" connection: 18 kW
''Dry heat" connection: 18 kW
Electrical connection:
208 V:
240 V:
440 V:
480 V**:
Notes:
Weight (Net): 135,5 kg
Weight (Gross):
Cubing packing:
Freight Class:
#AWG Wire size (140° F): 5 x 4 mm2
Recommended breaker:
208 V:
240 V:
440 V:
480 V:
** Other voltages on request
Thermal load latent: 3.529 kJ/h
Thermal load sensitive: 4.615 kJ/h
Airflow requirement (unit freestanding in room): 651 m3/h
Airflow requirement (one side of unit against a wall): 410 m3/h
Airflow requirement (two side of unit against a wall): 260 m3/h
SelfCooking Center® 101 G (10x1/1 GN)
Capacity (Steam pans):
Capacity (half size sheet pans):
Capacity (GN-container/grids): 10 x 1/1 GN
Loading for: 1/1, 1/2, 2/3, 1/3, 2/8 GN
Number of meals per day: 80-150
Width: 847 mm
Depth: 771 mm
Height: 1.017 mm
Minimum gap (left, right, back side): 50 mm
Recommended gap fo servicing (left side): 500 mm
Minimum gap if heat sources are acting on left side: 350 mm
Water connection (pressure hose): 3/4'' / Ø 1/2''
Note:
Water pressure (Flow pressure): 150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar
Minimum flow rate for soft water system: 6,3 l/h
Water drain: DN 50 mm
Note:
Connected load: 0,39 kW
Notes:
Gewicht (netto): 154.5 kg
Weight (Net):
Weight (Gross):
Cubing packing:
Freight Class:
Recommended breaker: 1 x 16 A
Mains connection: 1 NAC 230 V
Cable cross-section (Supplied with 8 ft. cord and 5-15 connector): 3 x 2,5 mm2
Gas supply/connection: 3/4"
Required gas pressure (natural gas):
Required gas pressure (LPG):
Connection flow pressure natural gas: 18 - 25 mbar
Anschlussfließdruck Erdgas L G25: 20 - 30 mbar
Connection flow pressure Liquid gas: 25 - 57,5 mbar
Anschlussfließdruck Flüssiggas G31: 25 - 57,5 mbar
Rated thermal load Liquid gas LPG total: 23 kW
Rated thermal load Liquid gas LPG ''Moist heat": 21 kW
Rated thermal load Liquid gas LPG ''Dry heat": 23 kW
Rated thermal load natural gas total: 21,5 kW
Rated thermal load natural gas ''Moist heat": 20 kW
Rated thermal load natural gas ''Dry heat": 21,5 kW
Thermal load latent: 3.529 kJ/h
Thermal load sensitive: 4.286 kJ/h
Airflow requirement (unit freestanding in room): 651 m3/h
Airflow requirement (one side of unit against a wall): 410 m3/h
Airflow requirement (two side of unit against a wall): 260 m3/h