| SelfCooking Center® 61 G (6x1/1 GN) |
| Capacity (Steam pans): |
|
| Capacity (half size sheet pans): |
|
| Capacity (GN-container/grids): |
6x1/1 GN |
| Loading for: |
1/1, 1/2, 2/3, 1/3, 2/8 GN |
| Number of meals per day: |
30-80 |
| Width: |
847 mm |
| Depth: |
771 mm |
| Height: |
757 mm |
| Minimum gap (left, right, back side): |
50 mm |
| Recommended gap fo servicing (left side): |
500 mm |
| Minimum gap if heat sources are acting on left side: |
350 mm |
| Water connection (pressure hose): |
3/4'' / Ø 1/2'' |
| Note: |
|
| Water pressure (Flow pressure): |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
| Minimum flow rate for soft water system: |
3,0 l/h |
| Water drain: |
DN 50 mm |
| Note: |
|
| Connected load: |
0,3 kW |
| Notes: |
|
| Gewicht (netto): |
126 kg |
| Weight (Net): |
|
| Weight (Gross): |
|
| Cubing packing: |
|
| Freight Class: |
|
| Recommended breaker: |
1 x 16 A |
| Mains connection: |
1 NAC 230 V |
| Cable cross-section (Supplied with 8 ft. cord and 5-15 connector): |
3 x 2,5 mm2 |
| Gas supply/connection: |
3/4" |
| Required gas pressure (natural gas): |
|
| Required gas pressure (LPG): |
|
| Connection flow pressure natural gas: |
18 - 25 mbar |
| Anschlussfließdruck Erdgas L G25: |
20 - 30 mbar |
| Connection flow pressure Liquid gas: |
25 - 57,5 mbar |
| Anschlussfließdruck Flüssiggas G31: |
25 - 57,5 mbar |
| Rated thermal load Liquid gas LPG total: |
12 kW |
| Rated thermal load Liquid gas LPG ''Moist heat": |
12 kW |
| Rated thermal load Liquid gas LPG ''Dry heat": |
12 kW |
| Rated thermal load natural gas total: |
11 kW |
| Rated thermal load natural gas ''Moist heat": |
11 kW |
| Rated thermal load natural gas ''Dry heat": |
11 kW |
| Thermal load latent: |
2.143 kJ/h |
| Thermal load sensitive: |
2.571 kJ/h |
| Airflow requirement (unit freestanding in room): |
342 m3/h |
| Airflow requirement (one side of unit against a wall): |
215 m3/h |
| Airflow requirement (two side of unit against a wall): |
137 m3/h |